The 2000 litre precast concrete septic tank Ireland customers rely on — manufactured in Enniscorthy, Co. Wexford by Murphy Precast. This two-chamber unit is built in accordance with EPA and Irish Building Regulations, making it a durable, ready-to-install wastewater treatment solution for rural homes, one-off builds, and residential developments without access to a public sewer.
If you need a 2000 litre precast septic tank in Ireland, Murphy Precast delivers a factory-quality unit ready for crane placement — saving time and reducing disruption compared to in-situ constructed alternatives. Manufactured to high quality standards at our Wexford facility.
| Specification | Detail |
|---|---|
| Capacity | 2,000 litres |
| Overall Dimensions | 2,498mm L × 1,178mm W × 1,215mm D |
| Weight | 2,100kg |
| Chamber Type | 2-chamber (Chamber 1 and Chamber 2) |
| Inlet | 4″ (100mm) inlet |
| Outlet | 4″ (100mm) outlet |
| Access Points | 2 access points |
In Ireland, nearly half a million homes use a domestic wastewater treatment system — the majority of which are septic tanks. A 2000 litre precast concrete septic tank Ireland is the ideal solution for rural homes, one-off houses, and sites without access to a public sewer. All installations must comply with the
EPA 2021 Code of Practice for Domestic Waste Water Treatment Systems
and Irish Building Regulations (Technical Guidance Document H).
Planning applications for new rural dwellings must demonstrate that the site is suitable for the proposed system. Murphy Precast septic tanks are manufactured in accordance with EPA and Irish Building Regulations, helping ensure your installation meets inspection requirements and local authority guidelines — whether you are replacing an old system or installing on a new site.

2000 litre precast concrete septic tank two-chamber precast concrete septic tank — 2,498mm L × 1,178mm W × 1,215mm D, 2,100kg. Manufactured in Enniscorthy, Co. Wexford.
The two-chamber layout allows solids to settle and partially digest in the first chamber before the liquid passes through to the second chamber for further settlement — a standard and effective approach to domestic wastewater primary treatment.
Delivered ready-to-install with integrated lifting points, this unit can be placed directly into a pre-prepared excavation by crane — making installation straightforward and efficient. No on-site casting or curing required.
Precast concrete tanks withstand heavy loads, soil pressure, and harsh Irish weather conditions. Unlike plastic alternatives, this tank will not deform, float, or degrade over time — providing long-term reliability with minimal maintenance.
Manufactured in accordance with EPA guidelines and Irish Building Regulations, helping ensure your system meets inspection requirements and local authority guidelines — essential for new build planning applications and replacement systems alike.
If you are installing a new septic tank in Ireland, there are several regulatory requirements to be aware of:
| Requirement | Detail |
|---|---|
| Planning applications | Must demonstrate site suitability and compliance with the EPA Code of Practice and Irish Building Regulations (TGD Part H). |
| Registration | All domestic wastewater treatment systems must be registered with your local authority. A once-off €50 registration fee applies via protectourwater.ie. |
| Siting requirements | Septic tanks must generally be sited at least 7 metres from any dwelling and within 30 metres of an access point for emptying — contact your local authority or a suitably qualified person for site-specific guidance. |
| De-sludging | Regular emptying by a registered contractor is required — keep receipts for at least 5 years. |
| Inspections | Local authorities carry out inspections under the EPA’s National Inspection Plan. Inspectors are appointed and approved by the EPA. |
Murphy Precast manufactures a full range of precast concrete products for residential, agricultural, and infrastructure projects. Products commonly specified alongside this tank include:
| Product | Relevance |
|---|---|
| ▶ Precast Water Storage Tanks | Off-mains rural homes frequently need both on-site wastewater treatment and clean water storage — commonly specified together on the same project. |
| ▶ Full Precast Tank Range | View the full range of Murphy Precast concrete tanks — including water storage, effluent, and oil interceptor units — to cover all site requirements. |
| ▶ Precast Effluent Storage Tanks | For agricultural or commercial sites requiring dedicated effluent storage alongside residential wastewater treatment. |
Looking to order a 2000 litre precast concrete septic tank in Ireland and want to discuss delivery logistics, lead times, or site suitability? Contact our Enniscorthy team directly — we’ll advise on what’s needed to get the tank to your location.
🕕 Old Dublin Road, Kilcannon, Enniscorthy, Co. Wexford
The Murphy Precast 2,000 litre septic tank measures 2,498mm in length, 1,178mm in width, and 1,215mm in depth. It weighs 2,100kg.
This is a two-chamber (2-chamber) precast concrete septic tank with two access points, a 4″ (100mm) inlet, and a 4″ (100mm) outlet.
Yes. Murphy Precast septic tanks are manufactured in accordance with EPA and Irish Building Regulations, helping ensure the system meets inspection requirements and local authority guidelines for new build planning applications and replacement installations.
Yes. All domestic wastewater treatment systems in Ireland must be registered with your local authority. Registration is done online at protectourwater.ie with a once-off €50 fee. New systems must be registered within 90 days of commissioning. Failure to register is an offence with a fine of up to €5,000.
The tank is delivered ready-to-install with integrated lifting points. It is placed by crane into a pre-prepared excavation — making installation straightforward and efficient with no on-site casting or curing required. (Delivery is subject to Location and circumstances)
Contact Murphy Precast directly — call +353 53 923 6348, email [email protected], or use our online contact form. Every site and project is different — our team will discuss your requirements and advise on logistics for your location regarding the 2000 litre precast concrete septic tank.